1/4'' Inch Golden Yellow Color 2V Water Control Valve 2W025-08 made of Superior Brass
Model No. | 2W025-08 |
Working Medium | Air,Water,Oil,Gas |
Motion Pattern | Direct Drive Type |
Type | Normal Close Type |
Aperture of Flow Rate | 2.5 |
Joint Pipe Bore | 1/4” |
Operating Temperature Rang | -5~80 |
Voltage Range | ±10% |
Operation Fluid Viscosity | 20 CST(below) |
Working Pressure(kgf/cm | Gas:0~7, Oil:0~5, Air:0~7, Water:0~5 |
Material of Oil Seal | NBR,EPDM Or Viton |
Outlook picture of 2W025-08
Drawings of 2W025-08
Sample of valve body
The Electromagnetic Valve Fault and Eliminate:
electromagnetic valve does not work after the power supply:
1, check the power supply wiring whether bad -)
connectors and wiring connection again;
2, check whether the power supply voltage in the plus or minus working range --) to switch to normal position;
3, whether the ring
sealing off -) to welding;
4, coil short circuit, replace the coil;
5, differential pressure is not appropriate to work -) -) or replacement of proportion adjustment pressure
difference electromagnetic valve;
6, fluid temperature is too high -) change of proportion of electromagnetic valve;
7, have impurities to make electromagnetic valve of the
main valve core and the moving core card die -) cleaning, such as seal damage the seal and install the filter should be changed;
8, the liquid viscosity is too large, high
frequency and life expectancy has to -) replacement products.
(2) the solenoid valves can't shut down:
1, the main valve core or moving iron core of seal is damaged, replace the seal;
2, fluid temperature, viscosity is too high -) change
of the electromagnetic valve;
3, have impurities into the solenoid valve core or moving iron core -) for cleaning;
Four, spring life have to or replace the spring deformation
5, orifice balance hole jam --) timely cleaning;
6, working frequency is too high, or life has to -) election products or replacement products.
(3) other situations:
1.internal leakage, check whether the seal is damaged, the spring is bad assembly.
2, outside leakage -) joint looseness or seal has bad -) screw or replace the seal;
3.electricity from time to tome noise -) leader on fasteners loose, tighten. Voltage fluctuation is not allowed within the scope of adjust voltage. Core surface impurities or
uneven absorption, clean or replace in a timely manner
Any question will be answered at once,If you have the current or future demand,plz contact us without any hesitation!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM