Place of Origin: | Ningbo, China |
Brand Name: | BRANDO |
Certification: | None |
Model Number: | BB08029101 |
Minimum Order Quantity: | 1000 |
---|---|
Price: | Negotiation |
Packaging Details: | Inner Box, Carton, Pallet |
Delivery Time: | Negotiation |
Payment Terms: | T/T, PayPal, Western Union |
Supply Ability: | 500000 set per month |
Type: | Type Solenoid Coil | Material: | Plastic, Brass |
---|---|---|---|
Product Name: | 6012 Type Solenoid Valve Coil | Voltage: | DC24V, AC110V, AC220V (±10%) |
Hole Size: | φ8mm | Power: | AC:5VA |
Color: | Black (Other Color Can Be Customized) | Application: | Type 6012 Plunger Valve 3/2 Way Direct Acting |
Insulation Class: | H, F | Connection Type: | DIN43650B |
Highlight: | Plunger Solenoid Valve Electrical Coil,BD-C Electrical Coil,6011 6012 Solenoid Coil |
6011 6012 Plunger Solenoid Valve BD-C DIN43650B Electrical Coil
This solenoid valve coil is suitable for the type 6012 plunger 3/2 way solenoid valve. A solenoid valve is a device that is used to cut off the circulation of water, oil, gas, and the like. Solenoid valves are commonly used in our daily chemical equipment pipelines, such as water plants, steam pipes, chemical equipment, but because of the different lengths of use of each substance, we are divided into normally open and normally closed solenoid valves. We choose to use the normally open solenoid valve or the normally closed solenoid valve difference and suggestion: the solenoid valve is divided into two types: normally closed type and normally open type: 1. Normally closed type means that the line is broken when the coil is not energized. 2. Normally open type means that the pipeline is open when the coil is not energized.
Technical parameter of 6011 / 6012 Type Solenoid Valve Coils:
Model number | BB08029101 |
Normal voltage | DC24V, AC110V, AC220V (±10%) (Other can be customized) |
Normal power | AC:5VA |
Material | Plastic, Brass |
Wire class | H, F |
Connection | DIN 43650B |
Application | Type 6011 / 6012 Plunger Valve 3/2 Way Direct Acting |
Hole diameter | 8 mm |
Height | 29 mm |
Width | 19.6 mm |
Main dimension of 6011 / 6012 Type Plunger Valve Solenoid Coil:
DIN 43650B connection of 6012 Type Electric Magnetic Coils:
Production of Type 6012 / 6011 Plunger Valve Electromagnetic Coil:
More details about 6012 / 6011 Type Solenoid Valve Coil AC220V For Plunger Valve in below Youtube Video:
The five main reasons why the solenoid valve does not work, have you encountered it?
In the common problems of solenoid valves, the problems that can not work normally after power-on are very common. So what is the problem? The following 5 reasons are for your reference:
1. The fluid pressure or the pressure difference of the task does not match. This will cause the solenoid valve to fail to work properly. The medium cannot pass. The working conditions of the solenoid valve cannot meet the practical working requirements and are not within the scope of the practical working environment.
Disposal method: Adjust the pressure or working pressure difference or change the appropriate product.
2. The valve core and the moving iron core are mixed with impurities and impurities. When the impurities enter the outside of the solenoid valve, the solenoid valve products will not work properly.
Disposal method: Stop the cleaning on the outside and install the filter valve before the valve.
3. Fluid viscosity or temperature does not fit, this is generally due to the wrong choice of the solenoid valve product model, perhaps the property of the media has changed.
Disposal method: Check the properties of the media, you can adjust the media properties to stop the adjustment, otherwise you need to change the appropriate products.
4. Before the valve filter or pilot valve hole infarction, this is also caused by too much impurities.
Disposal method: Invert the filter and pilot valve hole of the solenoid valve, and clean the filter or pilot valve hole. In addition, the medium reflecting the solenoid valve is required. Excessive impurities should be stopped in time.
5. When the task frequency is too high or the life is expired, the task frequency of too high will affect the normal operation of the solenoid valve. In addition, if the working time of the solenoid valve is too long and the life is expired, the solenoid valve will not work normally.
Disposal method: Reorganize the product model or change the new product. If the wrong operation and maintenance, maintenance and maintenance, will lead to the solenoid valve can not be used properly.
Welcome to your any question and inquiry!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM