Place of Origin: | Ningbo, China |
Brand Name: | BRANDO |
Certification: | None |
Model Number: | BB13644617 |
Minimum Order Quantity: | 500pcs |
---|---|
Price: | Negotiation |
Packaging Details: | inner boxes,cartons,pallets |
Delivery Time: | Negotiation |
Payment Terms: | T/T, PayPal, Western Union |
Supply Ability: | 100000pcs per month |
Hole Size: | 13.6mm | Height: | 44.3mm |
---|---|---|---|
Width: | 39.5mm | Voltage: | AC220V, DC24V |
Power: | 25VA, 20W | Connector: | 6.3x0.8mm |
Insulation Class: | F, H | Enameled Wire Material: | Copper |
Application: | LPG, CNG Reducer | ||
Highlight: | LPG CNG Solenoid Valve Coil,RGE RGE90 Solenoid Valve Coil,LPG CNG Repair Kit solenoid coil |
LPG CNG RGE RGE90 RG90 RGV Reducer Kit Solenoid Valve Coil
Users need to consider various issues when purchasing electromagnetic coils in order to choose the product that suits them:
1. The quality of the solenoid coil is a problem that the user should pay attention to when purchasing. In selecting materials, it is necessary to consider many environmental factors in use, such as the temperature of the environment, whether there is moisture and the like, so the solenoid valve is selected. At the same time, we should consider whether our materials are selected correctly, whether we need to choose BMC materials for plastics and skeleton materials, whether to choose PA66 nylon materials, etc., whether we need to choose high temperature resistance in enameled wire, etc. Need customers to consider.
2. In terms of size, it is necessary to know the size, height, and width of the coil of the solenoid valve coil that the customer needs. Whether it needs to be square or round, it is necessary to select the relative model according to the requirements of different solenoid valves.
3. The connection method, the customer needs pin type or lead type, according to the different link mode of the customer, different coils can be selected. For example, the coils such as HY-A and 0200 are pin type, and the standard of the pin is DIN43650A, 3130C, 4V110A, The coils such as 16431 are leaded.
When purchasing the electromagnetic coil, it is necessary to fully consider various factors to ensure that no accidents will occur in the application and reduce the troubles in use.
Solenoid Valve Coils (DC) and Electrical Polarity
A common question about solenoid valve coils is whether the electrical current polarity matters in a DC coil. Most coils with lead wires use the same color wire for both terminals and have no polarity markings. The answer is that polarity does not matter. You can connect the positive terminal to either of the two wires without affecting the operation of the valve.
Dimension of BB13644617 Solenoid Valve Coil :
Technical Data:
Solenoid Coil Production Line:
Attention:
1. This air suspension compressor pump solenoid coil is made of high quality components.
2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
3. Please double confirm the compatibility as well as the OEM number before purchasing.
4. Instruction is not included. Professional installation is recommended.
Steps and methods for properly installing a solenoid valve coil:
1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.
2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.
3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.
4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.
5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.
6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.
7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.
Product Features:
1. Using high quality wire which has UL approved; 2. Using high quality permeablity magnetic material which contain low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and so on.
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof coils and so on.
7. If you have special requirement, pls feel free to contact us.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM