Send Message
Home ProductsSolenoid Valve Coil

0545 Magnet Air Compressor Auto Drain Solenoid Valve Coil

0545 Magnet Air Compressor Auto Drain Solenoid Valve Coil

  • 0545 Magnet Air Compressor Auto Drain Solenoid Valve Coil
  • 0545 Magnet Air Compressor Auto Drain Solenoid Valve Coil
0545 Magnet Air Compressor Auto Drain Solenoid Valve Coil
Product Details:
Place of Origin: China
Brand Name: Brando
Certification: CE
Model Number: BB14542505
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Price: negotiation
Packaging Details: Inner Box, Carton, Pallet
Delivery Time: 4-8 days
Payment Terms: L/C, T/T, Western Union,Paypal, MoneyGram
Supply Ability: 500000 set per month
Contact Now
Detailed Product Description
Type: 0545 110-030 NASS Type Material: Thermoset Resin, Copper
Product Name: 0545 110-030 NASS Type Solenoid Valve Coil System 13 Voltage: AC220V AC110V/ DC12V DC24V (±10%)
Hole Size: 14.6 Mm Ambient Temperature: - 20 °C ~ + 50 °C
Application: Water Solenoid Valve And Electronic Drain Valve Insulation Class: F, H
Connection Type: DIN43650A Degree Of Protection With Connector: IP 65 (IP 67 On Request)
High Light:

0545 Solenoid Valve Coil

,

Auto Drain Solenoid Valve Coil

,

Nass Type 0545

0545 Magnet Air Compressor Auto Drain Solenoid Valve Coil

 

The electronic drain valve is mainly composed of a solenoid valve with 0545/0543 solenoid coil, a timer and a junction box. The automatic drain valve is set for a period of time to perform a drain operation on a regular basis.

1. The hot, humid and moisture-laden compressed air from the air compressor is first pre-cooled by air to the air heat exchanger; then the pre-cooled air is passed through the refrigerant in the air-to-refrigerant heat exchanger. The circulation loop is further cooled to exchange heat with the cold air that has been cooled from the evaporator to the pressure dew point to further reduce the temperature of the compressed air.

2. After that, the compressed air enters the evaporator and exchanges heat with the refrigerant. The temperature of the compressed air drops to 0 ° C - 8 ° C. The moisture in the air is precipitated at this temperature, and the water condensed in the compressed air is passed through the condenser. The oil and impurities are separated and discharged through the automatic drainer.

3. The dry low-temperature air enters the air to exchange heat with the air exchanger, and the temperature rises and then outputs.

 

Technical parameter of 0545 110-030 NASS Type Solenoid Valve Coil:

Model number BB14542505
Reference number 0545 110-030 NASS Type
Normal voltage AC220V / AC110V/ DC12V / DC24V (±10%)
Normal power AC: 22VA DC: 13W 20W
Ambient temperature - 20 °C ~ + 50 °C
Material Thermoset resin, Copper
Wire class F, H
Connection type DIN43650A
Application Water solenoid valve and electronic drain valve
Hole size 14.6 mm
Height 42 mm
Width 36 mm

 

Main dimension of Nass Type 0545 Electronic Drain Solenoid Coils:

0545 Magnet Air Compressor Auto Drain Solenoid Valve Coil 0

 

Phyical map of 113-030-0028 nass type electromagnetic coil:

0545 Magnet Air Compressor Auto Drain Solenoid Valve Coil 1

 

Applicatoin of nass type 113-030-0035 electric magnetic coil:

0545 Magnet Air Compressor Auto Drain Solenoid Valve Coil 2

 

More details about 0545 110-030 series Solenoid Coil can be found below the Youtube Video:


The diameter and turns of the wire and the material of the core determine the magnetic force of the solenoid valve coil​s:

Solenoid valve is affected by the solenoid valve coil and magnetic core, thereby generating magnetic force. So what does the magnitude of the magnetic force have to do with?

 

Generally, there are many factors that affect the magnetic force of solenoid valve coil, mainly the wire diameter of the coil and the magnetic conductivity area of the steel, that is, the magnetic flux. When the ac coil is pulled directly from the core, there is no need for a short circuit ring inside the core. If the ac current is abnormal, it will burn out the solenoid valve coil. Moreover, there is a short circuit ring inside the ac coil core, which can reduce vibration. Once the dc solenoid valve coil is removed from the core, the coil current will increase rapidly.

 

Because the wire diameter of the coil and the magnetic area of the magnetic steel directly affect the magnetic force of the solenoid valve coil, the dc coil can be removed from the core and move freely. The ac solenoid valve coil can not be pulled out from the iron core, once pulled out, will cause a surge in the coil current, seriously burned the coil. In addition, there is no need for any short circuit ring inside the dc coil core.

 

Solenoid valve coil magnetic force size, to a certain extent, determines whether the solenoid valve can operate normally. If the magnetic force is too large, the solenoid valve cannot operate. If the magnetic force is too small, the solenoid valve is not operational. The best way is to control solenoid valve coil magnetic force properly.​

Focus on your demands, Offer you best solution:


√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Contact Details
Ningbo Brando Hardware Co., Ltd

Contact Person: Mia

Tel: +8613454729544

Send your inquiry directly to us
Best Products
Other Products