Place of Origin: | Ningbo, China |
Brand Name: | BRANDO |
Certification: | CE, ISO |
Model Number: | SC |
Minimum Order Quantity: | 1 pc |
---|---|
Price: | Negotiation |
Packaging Details: | Inner Box, Carton, Pallet |
Delivery Time: | 4-7 work days |
Payment Terms: | L/C, T/T, PayPal, Western Union, MoneyGram |
Supply Ability: | 100000 pcs per month |
Product Series: | SC Standard Air Cylinder Tie-Rod | Bore Size (mm): | 32, 40, 50, 63, 80, 100, 125, 160, 200, 250 |
---|---|---|---|
Standard Stroke (mm): | 25, 50, 75, 80, 100, 125, 150, 160, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 | Acting Type: | Double Acting |
Operating Pressure Range: | 0.15 MPa To 1.0 MPa | Proof Pressure: | 1.5 MPa |
High Light: | Airtac Pneumatic Cylinder SC Series,Pneumatic Air Cylinder,Airtac Double Acting Cylinder |
Airtac Type SC Series Pneumatic Air Cylinder Double Acting
Pneumatic cylinders will vary in appearance, size and function, they generally fall into one of the specific categories shown below. However, there are also numerous other types of pneumatic cylinder available, many of which are designed to fulfill specific and specialized functions.
Single-acting cylinders
Single-acting cylinders (SAC) use the pressure imparted by compressed air to create a driving force in one direction (usually out), and a spring to return to the "home" position. More often than not, this type of cylinder has limited extension due to the space the compressed spring takes up. Another downside to SACs is that part of the force produced by the cylinder is lost as it tries to push against the spring.
Double-acting cylinders
Double-acting cylinders (DAC) use the force of air to move in both extend and retract strokes. They have two ports to allow air in, one for outstroke and one for instroke. Stroke length for this design is not limited, however, the piston rod is more vulnerable to buckling and bending. Additional calculations should be performed as well.
Specifications of SC Series Pneumatic Cylinder:
Bore Size (mm) | 32 | 40 | 50 | 63 | 80 | 100 | 125 | 160 | 200 | 250 | |
Acting Type | Double Acting | ||||||||||
Fluid | Air (to be filtered by 40μm filter element) | ||||||||||
Mounting Type | SC | Basic FA FB CA CB LB TC TCM1 | |||||||||
SCD, SCJ | Basic FA LB TC TCM1 | ||||||||||
Operating Pressure Range | 0.15 to 1.0 MPa (1.5 to 10.0 bar) (22 to 145 psi) | ||||||||||
Proof Pressure | 1.5 MPa (15 bar) (215 psi) | ||||||||||
Temprature (℃) | -20 to +70 | ||||||||||
Speed Range (mm/s) | 30 to 800 | 30 to 500 | |||||||||
Cushion Type | Variable cushion | ||||||||||
Adjustable Cushion Stroke (mm) | 21 | 28 | 29 | 36 | 40 | ||||||
Port Size | 1/8'' | 1/4'' | 3/8'' | 1/2'' |
Stroke of SC Series Pneumatic Cylinder:
Bore Size (mm) | Standard Stroke (mm) | Max. Standard Stroke | Max. Stroke |
32 | 25 50 75 80 100 125 150 160 175 200 250 300 350 400 450 500 | 1000 | 2000 |
40 |
25 50 75 80 100 125 150 160 175 200 250 300 350 400 450 500 600 700 800 900 1000 |
1200 | 2000 |
50 | 1200 | 2000 | |
63 | 1500 | 2000 | |
80 | 1500 | 2000 | |
100 | 1500 | 2000 | |
125 | 1200 | 2000 | |
160 | 1500 | 2000 | |
200 | 1500 | 2000 | |
250 | 1500 | 2000 |
Symbol of SC Series Pneumatic Cylinder:
Ordering Code of SC Series Pneumatic Cylinder:
Criteria for selection: Cylinder thrust:
Installation & Usage:
1. When load changes in the work, the cylinder with abundant output capacity shall be ed.
2.Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3.Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5.The medium used by cylinder shall be filtered to 40μm or below.
6.Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7.The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8.The cylinder shall avoid the influence of side load in operation to maintain the normal work of cylinder and extend the service life.
9. If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contact Person: Brandon Bao
Tel: 86-13454729544
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM