Send Message
Home ProductsPulse Jet Valve

ASCO Type SCG353 Series 1-1/2'' Inch SCG353A047 Dust Collector Diaphragm Pulse Jet Valve

ASCO Type SCG353 Series 1-1/2'' Inch SCG353A047 Dust Collector Diaphragm Pulse Jet Valve

  • ASCO Type SCG353 Series 1-1/2'' Inch SCG353A047 Dust Collector Diaphragm Pulse Jet Valve
ASCO Type SCG353 Series 1-1/2'' Inch SCG353A047 Dust Collector Diaphragm Pulse Jet Valve
Product Details:
Place of Origin: China
Brand Name: Brando
Certification: CE
Model Number: SCG353A047
Payment & Shipping Terms:
Minimum Order Quantity: 1 pc
Packaging Details: inner boxes,cartons,pallets
Delivery Time: 7 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 100000pcs per month
Contact Now
Detailed Product Description
Port Size: G1-1/2'' Action Type: Diaphragm Pilot Operated
Connection Type: Threaded Power: Solenoid
Structure: Diaphragm Valve Type: Right Angle
Application: Dust Collector System Voltage: AC220V, AC110V, AC24V, DC24V
Pressure Range: 0.3 To 0.8MPa Temperature Range: -5 To +55℃
High Light:

1-1/2'' Inch Pulse Jet Valve

,

SCG353A047 Diaphragm Valve

,

Dust Filter Pulse Jet Valve

ASCO Type SCG353 Series 1-1/2'' Inch SCG353A047 Dust Collector Diaphragm Pulse Jet Valve

This ASCO type 353 Series Pulse Valve is specially designed for dust collector system, combining high flow, long life and extremely fast opening and closing. High performance diaphragm valve with threaded port. Suitable for dust collector system, in particular for Concrete Processing, Grain, Agriculture and Feed, Metal Working (Abrasive Blasting), Food Processing, Foundries, Life Science and etc.

FEATURES
Designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing
Integral compression fittings for fast, easy, secure installation
The high quality diaphragms are reinforced and wear resistant to guarantee a long operating life
The integral operators are provided with epoxy moulded F-class coils. Various optional waterproof and explosionproof solenoids for use in potentially explosive atmospheres
The valves satisfy all relevant EC directives

 

Youtube Video About 353 Series Pulse Valve:

 

 

Technical Data:

Model No SCG353A047
Port Size  1-1/2Inch 
Number of Diaphragm  2
Media  Air 
Working Pressure  0.3`0.8Mpa 
Working Temperature  -5~+55℃
Function  Normally Closed 
Body Material  Aluminum Alloy 
Seal Material  NBR(common, all available)
Voltage  AC220V, AC110V, AC24V, DC24V

 

Overall Dimension:

D-BB14040007
Model No.
BB14040007
Ref No.
400425
Voltage
AC24V, AC110V, AC220V, DC12V, DC24V
Connection
DIN 43650A
Other can be customized, please contact us.
BAPC214041405-D

 

 

Model No.
BAPC214041405
Ref No.
C113827
NC/NO
NC
2 Way or 3 Way
2Way
Other can be customized, please contact us.
 

 

 

A047
Model No.
A047
Ref No.
C113827
Replace For
SCG353A047
Mounting Hole Dia.
8.5mm
Sealing Disc OD
/
SCG353A047
Ref. Number
SCG353A047
Working Pressure
0.3~0.8Mpa
Voltage
24V DC, 110V AC, 220V AC
Other voltages can be customized.
Diaphragm Nos
2
Port Size
G1-1/2''
Other requirement please contact.

 

Detais About SCG353A047 Solenoid Pulse Valve :

Detais About SCG353A047 Solenoid Pulse Valve :

 

Construction:

Part Name Material 
Solenoid Coil  Copper Wire 
Armature  Stainless Steel 
Diaohragm & Seals  NBR(common , all available)
Body  (diecast) Aluminum Alloy 
Screws  Stainless Steel 

 


Operation
When the remote pilot valve or the integral solenoid valve opens, pressure above the pilot diaphragm assembly and main diaphragm assembly is released (exhausted). This allow main line pressure to act against the underside of the main diaphragm-assembly, opening the main orifice. When the remote pilot valve or the integral solenoid valve closes, main line pressure bleeds to the top of the pilot diaphragm assembly and main diaphragm assembly. This closes the main orifice.

 

Installation
Valves have to be used according to the information stamped on nameplate and coil.
Clean and depressurize pipe line before installing valve.
Valve may be mounted in any position, although upright position always guarantees best performance. Direction of flow is marked with the letters "IN" at the valve inlet.
Connect piping to valve according to markings on nameplate with common fittings.
Reducing pipe connections may cause faulty operation.
Pipe strain should be avoided by proper support and alignment of piping.
Pressure-tightness will be effected by interposing and compressing an appropriate jointing medium outside the threads.
(Warning: when using tape or pipe compound, apply sparingly to male pipe threads only; if applied to valve threads, it may enter the valve and cause operational difficulty. Conical pipe connections have to be tightened carefully to avoid body damage.)
When tightening pipe, do not use valves as a lever. Wrenches applied to valve body or piping are to be located as close as possible to connection point.

 

Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Contact Details
Ningbo Brando Hardware Co., Ltd

Contact Person: Mia

Tel: +8613454729544

Send your inquiry directly to us
Best Products
Other Products