Place of Origin: | Ningbo, China |
Brand Name: | BRANDO |
Certification: | None |
Model Number: | BB10029519 |
Minimum Order Quantity: | 500pcs |
---|---|
Price: | Negotiation |
Packaging Details: | Inner Box, Carton, Pallet |
Delivery Time: | Negotiation |
Payment Terms: | T/T, PayPal, Western Union |
Supply Ability: | 500000 set per month |
Type: | Solenoid Coil | Material: | Pure Copper, Plastic |
---|---|---|---|
Product Name: | AMISCO Type Pneumatic Solenoid Valve Coil | Voltage: | DC12V/DC24V/DC36V/AC36V/AC110V/AC220V |
Hole Diameter: | 10 Mm | Power: | Electric, Magnetic |
Color: | Black (Other Color Can Be Customized) | Application: | Automatic Control Pneumatic Solenoid Valve Coil |
Insulation Class: | F. H | Connection Type: | Flying Lead Type |
Highlight: | Solenoid Coils,Solenoid Valve Coils,Coils For Solenoid Valves |
EVI 7/10 φ10 Diameter Flying Leads AMISCO Type Pneumatic Solenoid Coils DC12V / 24V
The solenoid valve is affected by the EVI 7/10 flying lead solenoid valve coil and the magnetic core, thereby generating a magnetic force. So what is the reason for the magnitude of the magnetic force?
Generally, there are many factors that affect the magnetic force of the solenoid valve coil, mainly because the wire diameter of the coil is related to the magnetic conductive area of the magnetic steel, that is, the magnetic flux. When the AC coil is directly pulled out from the core, a short-circuit ring is not required inside the DC coil core. If the AC power is not normal, the solenoid valve coil will be burnt. Moreover, there is a short-circuit ring inside the AC coil core to reduce vibration. Once the DC solenoid coil is removed from the core, the coil current will increase rapidly.
Technical parameter of EVI 7/10 Flying Leads AMISCO Type Pneumatic Solenoid Coil:
Model No. | BB10029519 |
Reference number | EVI 7/10 Flying Lead |
Normal voltage | DC12V/DC24V/AC110V/AC220V; or customized |
Normal power | DC: 6W AC: 85VA |
Insulation class | H, F |
Connection type | Wire lead type |
Application | Automatic Control Pneumatic Solenoid Valve Coil |
Weight | 67 g |
Hole size | 10 mm |
Height | 29.5 mm |
Main dimension of Lead type AMISCO replacement electromagnetic coils:
Detailed pictures of AC220V/110V EVI 7/10 φ10mm diameter solenoid valve coil:
Application of DC12V/24V AMISCO replacement Wire Lead Type Solenoid Coils:
EVI 7/10 Flying Leads AMISCO Type Solenoid Coil for optimized applications:
Whether the solenoid valve coil can achieve optimized application is directly related to the normal function of the entire solenoid valve device and the optimized application effect. So for everyone, in order to optimize the application of the entire solenoid valve, it is necessary to optimize the use of the coil. As far as the optimization of the coil is concerned, it is necessary for everyone to do the following to be well protected:
1. Purchase high-quality coil products of the corresponding specifications: For any product, the basic conditions for realizing the advantageous application are all that the product itself is very suitable and can also have very high quality. Therefore, everyone needs to ensure that they purchase the high-quality solenoid valve coil of the corresponding specifications, so that it is possible to optimize the application of the coil.
2. Ensure that the coil is in the best installation state: the solenoid valve coil plays a role of connection for the solenoid valve, and the good connection function is played. It is necessary for everyone to make the best efforts to ensure that it is at the best. The installation status can only be achieved.
3. Optimize the use of the coil: Because the application of the power supply is not good, too humid air and other factors, it will affect the application effect and service life of the solenoid valve coil. Therefore, in order to optimize the application of the coil, we also need to optimize the use of the coil as much as possible.
All of the above are fully implemented, and everyone can realize the optimal application of the solenoid valve coil.
Welcome to your inquiry!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM