Material: | Aluminum Alloy | Color: | Yellow, Blue |
---|---|---|---|
Acting Type: | Internal Piloted Type | Activate Time: | Less Than 0.05 Second |
Weight: | 151.5g | Volume: | 80.9 Cm³ |
Port Size: | G1/8" Inch | Power: | Solenoid,Pneumatic |
Connection: | Female Thread,Thread(NPT,BSP,BSPT) | Voltage: | DC12V DC24V AC110V AC220V AC380V |
High Light: | electric solenoid valve,solenoid pneumatic valve |
24VDC 5 way 1/8'' port 4V120-06 Pneumatic Air Solenoid Valves Internal Piloted Action In Automatic Winding Machine
Two-position three-way solenoid valves are usually used with single-acting pneumatic actuators. Two positions are controllable at two positions: on-off, three-way ventilation is provided by three channels. In general, one channel is connected to the air source, and the other two are connected. One channel is connected to the air inlet of the actuator, and one is connected to the exhaust port of the actuator. The specific working principle can refer to the working principle diagram of the single-acting pneumatic actuator.
PRODUCT FEATURES:
TECHNICAL DATA of 4V120-06 Pneumatic cylinder valves Internal piloted action:
MODEL | 4V110-06 | 4V120-06 | 4V130C-06 | 4V130E-06 | 4V130P-06 |
Position number | Two positions Five ways | Three positions Five ways | |||
Maximum pressure resistance | 1200kpa | ||||
Operating temperature | -5-60℃ | ||||
Voltage range | -15%~10% | ||||
Energy consumption | AC:2.5 VA DC:2.5w | ||||
Protection rate | IP 65 | ||||
Wiring form | Connector type | ||||
Maximum working frequency | 300 cycles per minute |
MAIN DIMENSION of 1/8'' inch hole 5 way 4V120-06 Pneumatic air electromagnetic valves:
Armature & Piston of 4V120-06 Pneumatic control solenoid valves Class F Insulation:
APPLICATION of 220VAC/DC24V 4V120-06 double solenoid coils pneumatic control valves:
Double-acting cylinder with 4V120 5/2 way pneumatic cylinder solenoid valves:
The double-acting cylinder is a solenoid valve that requires a two-position five-way. A pneumatic connector, PU tube is required to connect these components. The solenoid valve has five threaded holes, three on one side and two on the other. The larger one in the middle of the three holes is the air intake hole. The air intake hole is connected to the third joint and the two are the exhaust holes. The exhaust hole only needs to be equipped with a muffler. The other two holes on the other side are the working holes, which are the two holes on the front and rear end caps of the cylinder, so that they are basically assembled. Maintain the continuous airflow, and adjust the pressure of 4-5MPA through the pressure regulating valve to control the piston of the cylinder to reciprocate by energizing and de-energizing the solenoid valve.
Pneumatic solenoid valve installation precautions:
1. According to the fluid chemistry, select the appropriate pneumatic solenoid valve material, such as strong acid gas can not use the pneumatic solenoid valve made of ordinary steel.
2. Check the interface sealing condition of the pipe before installation to prevent the use of foreign matter in the pneumatic solenoid valve.
3. Pay attention to the correctness of the wiring when wiring, and prevent the pneumatic solenoid valve from being safely used due to incorrect wiring or the wrong direction of the coil.
Two main reasons for 4V120 pneumatic solenoid valve coil to burn out:
1) The coil temperature is too high.
2) The inside of the coil is filled with water.
The coil temperature is too high for several reasons:
1: The actual voltage fluctuation is too large, exceeding the rated voltage range. The domestic paint hung wire generally has a voltage deviation of 5%, and a good manufacturer can reach 10%.
2: The medium circulating in your solenoid valve may have impurities, which may be stuck. The force of the electromagnetic wire cannot open the solenoid valve, causing the electromagnetic coil to work all the time. The coil is energized for a long time, the temperature rises, and finally the word burns.
3: The starting power of the coil is not enough, so that the solenoid valve is always open, the coil heats up for a long time, the temperature rises, and finally the word burns.
4: Your PTC thermistor is broken, causing the solenoid valve not to be properly controlled.
Welcome to your enquiry!
Contact Person: Echo
Tel: +8613454729544
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM