Place of Origin: | Ningbo, China |
Brand Name: | BRANDO |
Certification: | CE, ISO |
Model Number: | FDF2AK |
Minimum Order Quantity: | 50pcs |
---|---|
Price: | Negotiation |
Packaging Details: | Box, Carton, Pallet |
Delivery Time: | 7 working days |
Payment Terms: | T/T, Western Union, Paypal |
Supply Ability: | 100000 pcs per month |
Product Name: | Refrigeration Solenoid Valve | Normal Position: | Normally Open |
---|---|---|---|
Orifice Size: | 1.8mm | Tube OD: | 1/4'' |
Working Pressure: | 0 To 2.1 MPa | Max Operating Pressure: | 4.5 MPa |
Actuation: | Direct Operated | Working Medium: | HCFC, HFC Refrigerants, Etc |
Voltage: | 12VDC, 24VDC, 24VAC, 110VAC, 220VAC | Wiring Type: | Flying Leads |
Application: | Air Conditioner, Heat Pump, Ice Maker, Freezer, Cooler, Etc | ||
Highlight: | Refrigeration Solenoid Valve Normally Open,Sanhua Normally Open Solenoid Valve,Sanhua FDF2AK01 |
FDF2AK01 Sanhua Type Refrigeration Solenoid Valve Normally Open 24V 110V 220V
FDF2AK series solenoid valves are direct operated, normally open solenoid valves, mainly used in refrigerant control of various
devices such as refrigerating and freezing systems, air conditioners and heat pumps.
Features:
1. Compact design
2. Low energy consumption
3. Excellent operation performance
General Specifications:
1. Applicable for all common HCFC, HFC refrigerants such as:
R22, R134a, R404A, R407C, R410A, R507, R407A/F, R448A/R449A, R452A, R450A/R513A1)
2. Medium temperature TS min./max.: -30°C / 120°C
3. Ambient temperature: -30°C / +50°C
4. Relative humidity: 0 to 95% RH
5. Installation position:
1) Liquid, suction and discharge line
2) Coil upwards, coil axis ±15° tolerance versus vertical axis
3) Flow direction corresponds to the arrow
Technical Data:
Model No
|
Function
|
Operation
|
Orifice
|
Kv (m³/h)
|
MOP
|
Max.
OPD
|
Min.
OPD
|
Connection
OD
|
FDF2AK01
|
2 Way
NO
|
Direct Acting
|
1.8mm
|
0.05
|
45 bar
|
21 bar
|
0 bar
|
1/4''
(Φ6.35mm)
|
Our Production:
Related Products:
![]() |
![]() |
![]() |
![]() |
Solenoid Valve | 4 Way Reversing Valve | Expansion Valve | Hot Gas Bypass Valve |
![]() |
![]() |
![]() |
![]() |
Ball Valve | Check Valve | Sight Glass | Access Valve |
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Contact Person: Mr. Brandon Bao
Tel: 86-13454729544
Fax: 86-574-83879820
3'' DMF-Z-76S BFEC Diaphragm Pulse Jet Solenoid Valve For Bag Filter
CA25DD Goyen Type DD Series Pulse Jet Diaphragm Valve For Dust Collector
1'' SCG353A044 ASCO Type Diaphragm Pulse Jet Valve For Dust Removal
EVR 3 NC 032F8107 1/4'' Danfoss Type Refrigeration Solenoid Valve 220VAC
1028/3 Castel Type 3/8'' Refrigeration Solenoid Valve HM2 220VAC 230VAC
EVRA 40 EN-JS1025 Danfoss Type Ammonia Solenoid Valve 042H1128 042H1132
C113443 C113444 Diaphragm For ASCO Pulse Valve SCG353A043 SCG353A044
Diaphragm For BFEC Pulse Valve 1.5'' DMF-Z-40S DMF-ZM-40S DMF-Y-40S
K7600 K7601 Diaphragm Kit For Goyen Pulse Solenoid Valve CA76T CA76MM