Home ProductsRefrigeration Solenoid Valve

032L1240 s Type EVR20 Series 7/8" Refrigeration Valve Normally Closed ODF Solder Brass Body Without Coil

032L1240 s Type EVR20 Series 7/8" Refrigeration Valve Normally Closed ODF Solder Brass Body Without Coil

    • 032L1240 s Type EVR20 Series 7/8" Refrigeration Valve Normally Closed ODF Solder Brass Body Without Coil
    • 032L1240 s Type EVR20 Series 7/8" Refrigeration Valve Normally Closed ODF Solder Brass Body Without Coil
    • 032L1240 s Type EVR20 Series 7/8" Refrigeration Valve Normally Closed ODF Solder Brass Body Without Coil
    • 032L1240 s Type EVR20 Series 7/8" Refrigeration Valve Normally Closed ODF Solder Brass Body Without Coil
    • 032L1240 s Type EVR20 Series 7/8" Refrigeration Valve Normally Closed ODF Solder Brass Body Without Coil
  • 032L1240 s Type EVR20 Series 7/8" Refrigeration Valve Normally Closed ODF Solder Brass Body Without Coil

    Product Details:

    Place of Origin: China
    Brand Name: Brando
    Certification: CE
    Model Number: EVR20-078S

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 pc
    Packaging Details: inner boxes,cartons,pallets
    Delivery Time: 7 working days
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 100000pcs per month
    Contact Now
    Detailed Product Description
    Port Size: 7/8 Inch Coil: No
    Connection Type: ODF Solder Valve Operation: Servo- Diaphragm
    Body Material: Brass Application: Refrigeration Parts
    Refrigerant: R22 R404A R407A R407C R125 R134a R152a

    032L1240 s Type EVR20 Series 7/8 '' Refrigeration Valve Normally Closed ODF Solder Brass Body Without Coil

    Causes and troubleshooting methods:

    1. When the solenoid directional valve coil is open, short-circuited or burned out, it cannot be attracted, causing the slider to not move. Should be replaced. The armature of the solenoid valve is stuck and cannot move, causing the slider to not move. The valve body can be opened for cleaning and adjustment.

    2. The flow direction of the solenoid valve is reversed, causing the valve core not to move. The flow direction should be adjusted. The high temperature, high pressure of the system and impurities in the machine cause the slider to deform and get stuck. Should be replaced as well.

    3. The hole on the valve is blocked or broken; or the system is severely leaked and the slider does not move. Clean the hole tube or sleeve weld with a copper tube slightly thicker than the broken hole tube. There is dirt in the valve, damage to the valve seat or valve needle, and the spring force is too small, causing the solenoid valve to close tightly. Clean and adjust or replace the spring.

     

    Dimension:

    032L1240 s Type EVR Series 7/8'' Solenoid Valve

    Data sheet of EVR Series:

    Type
    Connection size (inch)
    Connection size
    (mm)
    Max. working Pressure
    (bar)
    Kv value
    (m3/h)
    Code NO.
    EVR 2
    1/4
    -
    45.2
    0.15
    032F1201
    -
    6
    45.2
    0.15
    032F1202
    EVR 3
    1/4
    -
    45.2
    0.26
    032F1206
    3/8
    -
    45.2
    0.26
    032F1204
    -
    6
    45.2
    0.26
    032F1207
    -
    10
    45.2
    0.26
    032F1208
    EVR 6
    1/2
    -
    45.2
    0.80
    032L1209
    3/8
    -
    45.2
    0.80
    032L1212
    -
    10
    45.2
    0.80
    032L1213
    -
    12
    45.2
    0.80
    032L1236
    EVR 10
    1/2
    -
    35
    1.9
    032L1217
    -
    12
    35
    1.9
    032L1218
    5/8
    16
    35
    1.9
    032L1214
    EVR 15
    7/8
    22
    32
    2.6
    032L1225
    5/8
    16
    32
    2.6
    032L1228
    EVR 20
    7/8
    22
    32
    5.0
    032L1240
    1 1/8
    -
    32
    5.0
    032L1244
    -
    28
    32
    5.0
    032L1245
    7/8
    22
    32
    5.0
    032L1264
    EVR 22
    1 3/8
    35
    32
    6.0
    032L3267
    EVR 25
    1 1/8
    -
    32
    10.0
    032L2201
    -
    28
    32
    10.0
    032L2206
    1 3/8
    -
    32
    10.0
    032L2207
    1 3/8
    -
    32
    10.0
    032L2208
    EVR 32
    1 5/8
    -
    32
    10.0
    042L1104
    -
    35
    32
    16.0
    042L1105
    -
    35
    32
    16.0
    042L1106
    -
    42
    32
    32
    042L1108
    EVR 40
    1 5/8
    -
    32
    32
    042L1110
    2 1/8
    -
    32
    32
    042L1112
     
    42
    32
    32
    042L1114

     

    Feature:
    Complete range of solenoid valves for refrigeration, freezing and air conditioning plant
    Supplied in versions normally closed (NC) and normally open (NO) with de-energized coil
    Wide choice of coils for a.c. and d.c.
    Suitable for all fluorinated refrigerants,including flammable refrigerants
    Designed for media temperatures up to 105 °C
    MOPD up to 25 bar with 12 W coil
    Flare connections up to 5/8 in.
    Solder connections up to 2 1/8 in.
    Extended ends on solder versions make the installation easy. It is not necessary to dismantle the valve when soldering in.
    Available in flare, solder and flange conection versions

     

    Focus on your demands, Offer you best solution:
    √ Contact us if some points you have doubt
    √ Contact us if somewhere need to change
    √ Contact us if not the one you are looking for
    √ Contact us if you are doing designing

     

    Welcome to your any question and inquiry!

     

    Contact Details
    Ningbo Brando Hardware Co., Ltd

    Contact Person: Brandon

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products