Home ProductsPneumatic Pulse Valve

CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V

CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V

    • CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V
    • CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V
    • CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V
    • CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V
  • CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V

    Product Details:

    Place of Origin: CHINA
    Brand Name: Brando
    Certification: CE
    Model Number: CA62MM

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Price: Negotiation
    Packaging Details: Inner Box, Carton, Pallet
    Delivery Time: 4-9 days
    Payment Terms: T/T, Western Union, L/C, MoneyGram, D/P, D/A
    Supply Ability: 100000 pcs per month
    Contact Now
    Detailed Product Description
    Product Name: CA62MM Goyen Type Pulse Jet Valve Port Size: 2 1/2''
    Valve Type: Full Immersion Valve Connection Type: Manifold Flat Mounted
    Body Material: Aluminum Temperature: -5℃~+55℃
    Pressure: 0.3MPa~0.8MPa Diaphragm Material: Buna(Nitrile)
    Number Of Diaphragms: 2 Voltages: AC24V, AC110V, AC220V, DC12V, DC24V

    CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V

     

    Brando has replacement pulse jet valves and repair kits for all major pulse jet valve brands and models. Generally, our diaphragm repair kits are cheaper than those purchased directly from the original manufacturer.

     

    Keeping the bag filter pulse valve in good working condition is the key to maintaining the efficiency of the dust collection system. The diaphragm in the pulse valve needs to be replaced regularly, usually every few years (depending on the application). Keeping the pulse valve of the bag filter in good working condition will have a huge impact on the efficiency and operation of the system.

     

    YouTube video of CA62MM Full Immersion Manifold Mounted Valve:

     

    Techincal data of Goyen Type MM Series Manifold Flat Mount Valves:

    Model No
    CA25MM
    CA40MM
    CA50MM
    CA62MM
    CA76MM
    CA102MM
    Nominal Size
    25
    40
    50
    62
    76
    102
    Port Size
    mm
    25
    40
    50
    62
    76
    102
    inch
    1''
    1 1/2''
    2''
    2 1/2''
    3''
    3 1/2''
    4''
    Pressure Range
    0.3 to 0.8MPa
    Temp. Range
    Nitrile seals
    -40 to 82℃
    Viton seals
    -29 to 232℃

     

    Overall dimension of CA62MM Full Immersion Pulse Jet Valve:

    CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V

    Details display of CA62MM Manifold Flat Mounted Diaphragm Valve:

    CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V

     

    Main Parts of Full Immersion Manifold Flat Mount Dust Collector Valve:

     

    CA62MM 2 1/2'' Full Immersion Manifold Flat Mount Pulse Jet Valve In Square Tank AC220V AC110V

     

    What is a Dust Collector Pulse Jet Valve?
    Diaphragm pulse valves are the most important components of a baghouse pulse jet cleaning system.

    On a pulse jet baghouse pulse valves (also called diaphragm valves) control the release of air pulses during the cleaning cycle. When the baghouse control board or timer board initiates a cleaning cycle it sends an electrical signal to the solenoids, when then activate the pulse valve. Inside the pulse valve, a rubber diaphragm opens and closes to release the compressed air stored in the air header tank. The air then passes through the valve into the blow pipes above the filters and then is directed down into the filters to clean them.

     

    How Can Replacing My Pulse Valves/Diaphragm Valves Save Me Money?
    The cost of pulse valves is minuscule when compared to the potential savings. Typically, replacing worn out diaphragms in a systems pulse valves will result in 10% or longer filter life, reduction in compressed air use by 15% or more! Additionally, when pulse valves are not in good condition the filters are not cleaned adequately. This leads to higher differential pressures which can lead to loss of suction throughout the system, higher fan pulls (meaning higher electricity bills) and other delays and production losses from under-performing dust collection system.

     

    Focus on your demands, Offer you best solution:

     

    √ Contact us if some points you have doubt

    √ Contact us if somewhere need to change
    √ Contact us if not the one you are looking for

    √ Contact us if you are doing designing

     

    Welcome to your any question and inquiry!

    Contact Details
    Ningbo Brando Hardware Co., Ltd

    Contact Person: Echo

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products