Send Message
Home ProductsPulse Jet Valve

220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector

220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector

  • 220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector
  • 220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector
  • 220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector
  • 220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector
220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector
Product Details:
Place of Origin: CHINA
Brand Name: Brando
Certification: CE
Model Number: DMF-Y-102S
Payment & Shipping Terms:
Minimum Order Quantity: one set
Price: negotiation
Packaging Details: Inner Box,Carton,Pallet
Delivery Time: 4-9 days
Payment Terms: T/T, Western Union, L/C, MoneyGram, D/P, D/A
Supply Ability: 150000 pieces per month
Contact Now
Detailed Product Description
Port Size: G 4'' Inch Media: Clean Air
Application: Dust Cleaner Equipment Material: Aluminum
Power: Solenoid,Pneumatic Number Of Diaphragm: 2
Pressure: 0.3MPa~0.6MPa Structure: Diaphragm
Temperature Of Media: -35℃~+45℃ Voltage: AC110V/AC220V/DC24V/12VDC
High Light:

pulse jet valves

,

solenoid pulse valve

C220V DC 24V 4'' Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector

 

Description:

DC24V DMF-Y-102S 4″ tank mounted immersion diaphragm valve, good quality diaphragm quality 1. Tank mounted diaphragm valve system with special springless piston/diaphragm design offers highest peak pressure and best flow performance operating features required for dust collector applications. 2. The high quality diaphragm guarantees a long operating life and a large temperature range. 3. Possible to apply different combinations of pitch distances and up to 24 valves

 

DC24V DMF-Y-102S 4″ tank mounted immersion diaphragm valve, good quality diaphragm quality

1. Tank mounted diaphragm valve system with special springless piston/diaphragm design offers highest peak pressure and best flow performance operating features required for dust collector applications.
2. The high quality diaphragm guarantees a long operating life and a large temperature range.
3. Possible to apply different combinations of pitch distances and up to 24 valves..
4. Each to connect to other tank systems. Service connections for different accessories such as: filter regulator, pressure gauge, safety and automatic/manual drain valve.
5. Several blow pipe connections available, such as: quick mount, push-in, hose or threaded connection.

 


Technical data chart of  DMF Y series solenoid pulse valves in industrial filter use:

Model Numbers DMF-Y-25 DMF-Y-40S DMF-Y-50S DMF-Y-62S DMF-Y-76S DMF-Y-102S

Port size

G1'' G1 1/2''

G2''

G2 1/2''

G3''

G4''

Membrane sizes
(φ66 smaller)
φ96 φ112 φ160 φ188 φ202 φ255
CV values 30.53 53.47 71.47 150.85 186.66 313.09
Blowing area (m2) 8-10 12-16 18-28 27-38 37-65' 70-90
Weighgt (kg) 0.75 1.2 2.35 3.2 4.05 6.65
Environment Temperature -25℃-80℃ or customized
Relative Humidity ≤85%
Working Medium Clean Air
Protection class IP 65
Service life cycle Over million times
Voltages AC110V/AC220V/DC12V/DC24V/12VDC

 
Overall dimension of DMF-Y-102S Pneuamtic Pulse Solenoid Valve Aluminum Body for Dust Collector:
220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector 0
 
Detail Images Of DMF Series Control Solenoid Valve:
220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector 1
Tips: All accessories can be sold separately as repair parts (Diaphragm, Solenoid Coil, Armature Assembly) 

 

Youtube video of DMF  Dust Collector Pulse Solenoid Valve


Working place view of DMF clean air solenoid pulse jet valve single diaphragm:
220V DC 24V 4" Inch DN102 DMF-Y-102S Electromagnetic Pulse Control Valve For Dust Collector 2
 
Common faults and repair methods of DMF membrane pulse solenoid valve:
1. The spring is damaged. The spring on the pulse valve spool is easily damaged. The appearance is that the pulse valve is deflated to the blow port for a long time. The treatment method is to replace the spring.
 
2. the valve core dirt, because the intake air is not clean, causing the fouling of the valve core, resulting in the appearance of long-term intake of the nozzle or the pulse valve does not work after the power, the treatment method is to clean the valve core.
 
3. the diaphragm is damaged, after long-term work, the diaphragm is easy to fatigue, oxidation, etc., resulting in the appearance of long-term deflation of the pressure relief port, the pulse valve does not work, the treatment is to replace the diaphragm.
 
4. The rubber pad is damaged. After the use time is long, the rubber pad on the pulse valve spool is easily damaged. The appearance is that the pulse valve is deflated to the blowing port for a long time. The treatment method is to replace the rubber pad.
 
5. The orifice is blocked or damaged. The intake air is not clean and the throttle hole is blocked. The appearance is that the pulse valve is deflated to the nozzle for a long time. The treatment method is to clean the orifice; the orifice is damaged or missing, and the orifice is made. Loss of interception, resulting in abnormal pressure relief, the appearance of the pulse valve after the power is activated, the pressure relief port deflation, but the pulse valve is not sprayed, the treatment is a replacement orifice.
 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Contact Details
Ningbo Brando Hardware Co., Ltd

Contact Person: Brandon

Tel: +8613454729544

Send your inquiry directly to us
Best Products