Home ProductsPneumatic Pulse Valve

110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System

110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System

    • 110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System
    • 110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System
    • 110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System
    • 110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System
  • 110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System

    Product Details:

    Place of Origin: China
    Brand Name: Brando
    Certification: CE
    Model Number: CA25T

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Packaging Details: Inner Box, Carton, Pallet
    Delivery Time: 4-7 days
    Payment Terms: L/C, T/T, Western Union,Paypal, MoneyGram
    Supply Ability: 80000 sets per month
    Contact Now
    Detailed Product Description
    Place Of Origin: Zhejiang China Port Size: G1 DN25
    Connection Type: Female Thread Nonimal Diameter: φ25mm
    Body Material: Aluminum Voltages: DC24V, AC110V, AC220V, AC230V
    Diaphragm Material: Nitrile Or Viton Working Pressure: 0.3-0.8 MPa
    Environment Temperature: -5℃-55℃ Model Number: CA25T

    110V 220V AC 24V DC DN25 G 1 CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust-collect System

     

    DESCRIPTION
    High performance diaphragm valve with threaded connection. Aluminum material body more light and convenient to change .Outlet at 90° to inlet.

    Goyen type T-series is designed for dust collect in factory,grain agriculture and feed and so on. These power pulse valves can be orientated in any position other than upside down or inverted. The temperature range of the threaded valves depends on the chosen model and diaphragm:
    1. Nitrile diaphragms: -40 °C (-40°F) to 82°C (179.6°F)
    2. Viton diaphragms -29°C (-20.2°F) to 232°C (449.6°F)

     

    SUITABLE FOR
    Dust collector applications, in particular for reverse pulse jet filter cleaning and its variations, including bag filters, cartridge filters and envelope filters, ceramic filters and sintered metal fibre filters.

     

    Main dimension of G 1 DN25 CA25T Goyen Type Dust Collector Pulse Valve:

    110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System

     

    Technical parameters of Goyen Type T Series Reverse Pulse Jet Valves:

    Model numbers CA15T CA20T CA25T CA35T CA40T CA50T CA62T CA76T
    Nonimal diameter φ15 φ20 φ25 φ35 φ40 φ50 φ62 φ76
    Port size G1/2'' G3/4'' G1'' G1-1/4'' G1-1/2'' G2'' G2-1/2'' G3''
    Weighgts (kg) 0.6 0.6 0.72 1.1 1.5 2.9 3.4 4.8
    Operation Internal pilot
    Working pressure 0.3-0.8 mpa
    Environment temperature -5℃-55℃
    Relative Humidity ≤85%
    Operating medium Compressed air
    Protection class IP 65
    Service life Over 1000000 times
    Voltages DC24V, AC110V, AC220V, AC230V

     

    Details of G1 CA25T Goyen Type Diaphragm Valve In Reverse Pulse Jet System:

    110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System

    Tips: All accessories can be sold separately as repair parts (Diaphragm, Solenoid Coil, Armature Assembly)

     

    Individual Packing of G1 CA25T Goyen Type Impulse Diaphragm Valve In dust collector:

    110V 220V AC 24V DC DN25 1 Inch CA25T Goyen Type Aluminum Body Pneumatic Diaphragm Valve For Dust Collect System

    Youtube video of CA25T G1 Goyen Type Dust Collector Pulse Solenoid Valve:

     

    MAINTENANCE
    Before conducting any maintenance activity on the system ensure that components are fully isolated from pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled. Diaphragm and pilot inspection should be conducted annually.

     

    INSTALLATION
    1. Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank.
    2. Ensure tank and pipes are free from dirt, rust or other particulate.
    3. Ensure supply air is clean and dry.
    4. Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself.
    5. Make electrical connections to solenoid or connect RCA pilot port to pilot valve (RCA valves only).
    6. Apply moderate pressure to system and check for installation leaks.
    7. Fully pressurise system.
    8. Test fire and listen for proper actuation and crisp pulse noise.

     

    Focus on your demands, Offer you best solution:

     

    √ Contact us if some points you have doubt

    √ Contact us if somewhere need to change
    √ Contact us if not the one you are looking for

    √ Contact us if you are doing designing

     

    Welcome to your any question and inquiry!

    Contact Details
    Ningbo Brando Hardware Co., Ltd

    Contact Person: Kyle

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products