Send Message
Home ProductsRefrigeration Solenoid Valve

032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia

032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia

  • 032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia
  • 032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia
  • 032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia
  • 032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia
032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia
Product Details:
Place of Origin: China
Brand Name: Brando
Certification: CE
Model Number: EVRA 25
Payment & Shipping Terms:
Minimum Order Quantity: 1 set
Packaging Details: Inner Box, Carton, Pallet
Delivery Time: 4-8 days
Payment Terms: L/C, T/T, Western Union,Paypal, MoneyGram
Supply Ability: 5000 sets per month
Contact Now
Detailed Product Description
Ref Number: 032F6225(Without Coil), 032F803432(With Coil) Connection Size: 1'' Inch, DN25
Connection Type: Steel Flange Set Operation: Servo Piston Operated
Function: 2-way NC (Normally Closed) Ambient Temperature: -40 To 80 °C
Body Material: Cast Iron Voltages: 110VAC, 220VAC, 230VAC, 12VDC, 24VDC
Refrigerants: R134a R22 R401A R402A R404A R407A R407B R407C R407F R409A R410A R421A R502 R507 R717 Max. Working Pressure: 42 Bar
High Light:

normally closed solenoid valve

,

liquid line solenoid valve

032F6225 032F803432 EVRA 25 s Type Servo-Piston Operated Flange Solenoid Valve For Ammonia

 

Product overview of 032F6225 032F803432 EVRA 25 s Type Servo-Piston Operated Flange Solenoid Valve For Ammonia:

The EVRA 25 s 032F6225 ammonia solenoid valve is used for automated opening and closing in ammonia network in both liquid and

gaseous phases. The EVRA valve is sold dismembered with body + flange set + coil supplied. In addition to this convenience, repairs are sold

separately. Thus, the valve can be repaired in the pipeline without removal, giving more agility and reliability to the process.

 

Main dimension of EVRA 25 s Type Flange Ammonia Solenoid Valve:

032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia 0  032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia 1

 

Technical parameters of EVRA 25 s Type Flange Solenoid Valve For Ammonia:

 

Type Opening differential pressure with standard coil ( ∆p bar) Temperature of medium (°C) Max. working pressure (bar) kv-value (m³/h)
Min. Max. (= MOPD) liquid²)
10W AC 12W AC 20W DC
EVRA 3 0.00 21 25 14 -40 to 105 42 0.23
EVRA 10 0.05 21 25 18 -40 to 105 42 1.5
EVRAT10 0.00 14 21 16 -40 to 105 42 1.5
EVRA 15 0.05 21 25 18 -40 to 105 42 2.7
EVRAT15 0.00 14 21 16 -40 to 105 42 2.7
EVRA 20 AC 0.05 21 25 13 -40 to 105 42 4.5
EVRA 20 DC 0.05 19 21 16 -40 to 105 42 4.5
EVRAT20 0.00 14 21 13 -40 to 105 42 4.5
EVRA 25 0.20 21 25 14 -40 to 105 42 10.0
EVRA 32 0.20 21 25 14 -40 to 105 42 16.0
EVRA 40 0.20 21 25 14 -40 to 105 42 25.0

 

Details of 032F6225 032F803432 EVRA 25 s Type Refrigeration Solenoid Valve:

032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia 2

 

Packing display of 032F6225 032F803432 EVRA 25 S Type Flange Valve:

032F6225 032F803432 EVRA 25 s Type Servo Piston Operated Flange Solenoid Valve For Ammonia 3

 

Video display of 032F6225 032F803432 EVRA 25 s Type Ammonia Valve:

 

Instructions to the Welder
1. Always use TIG / Argon welding as the root run, to avoid slag and debris entering the valve house.
2. Complete the welding process according to local legal requirements.
3. Inspect the inside around the welding and remove all debris.

 

Instructions to the Installer
1. Clean the pipes and valve houses with dry air (no water, no sandblasting).
2. Lubricate valve housing sealing surfaces (e.g. with refrigerant oil).
3. Follow the valve installation instructions.
4. Pressure test the system with dry air or inert gas (no water).

 

Instructions to the Supervisor
1. Build up the system in sections. For example, have valve trains or valve stations pre-manufactured before being shipped on site, or make it in a separate clean workshop on site, where welding and cleaning procedures can be easily controlled.
2. Evacuate the sections to verify that there is no water left in the system.
3. Seal and pressurize finished sections slightly with inert gas.
4. Evacuate down to 5-10 mbar before charging refrigerant.
5. Run free and clean filters frequently for 24-48 hours.

 

Focus on your demands, Offer you best solution:

 

√ Contact us if some points you have doubt

√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for

√ Contact us if you are doing designing

 

Welcome to your any question and inquiry!

Contact Details
Ningbo Brando Hardware Co., Ltd

Contact Person: Echo

Tel: +8613454729544

Send your inquiry directly to us
Best Products
Other Products