Home ProductsSolenoid Valve Diaphragm

Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material

Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material

    • Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material
    • Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material
    • Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material
    • Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material
  • Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material

    Product Details:

    Place of Origin: China
    Brand Name: OEM
    Certification: ISO、CE
    Model Number: 2W400

    Payment & Shipping Terms:

    Minimum Order Quantity: 1Pcs,Sample Available
    Price: negotiation
    Packaging Details: PVC bag, inner box, carton, than packed by pallet; also can be packed by color card and can be customized
    Delivery Time: 7 working days
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 100000pcs per month
    Contact Now
    Detailed Product Description
    Material: NBR Media: Water,Oil
    Product Name: Solenoid Water Valve Diaphragm Working Pressure: 0.2~0.6MPa
    Color: Black Temperature: -20℃~80℃

    0.2~0.6Mpa Working Pressure Solenoid Water Valve Diaphragm 2W400 MOQ As Low As 1 Pc

     

    The diaphragm is a flexible mechanism that requires frequent opening and closing operations to control air circulation, and requires good flexibility. It also requires as high a sealing as possible, so the material of the diaphragm is directly related to the diaphragm.
     
    Service life and effectiveness In other words, the quality of the diaphragm directly affects the stability of the machine, and it is directly related to the cost of the equipment. The general diaphragm has a promise of service life or number of movements. The use of high-quality diaphragm can directly reduce the work. The cost of using the device. There is a small hole in each diaphragm, which is a pressure regulating hole.
     
    When installing the diaphragm, please pay attention to the small hole must be aligned with the direction of the water inlet. If the installation error valve will leak or close, it will affect the normal use of the solenoid valve.
     
    Model 2w400-40 water valve diaphragm
    Center distance φ98
    Outside diameter /
    Hole number for mounting 4
    Working temperature -20℃--80℃
    Working pressure 0.2Mpa-0.6Mpa
    Working medium Water, Clean Air
    Diaphragm working life More than 1 million cycles

     

    Practical sample picture of 2W400 series diaphragm

    Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material

    Drawings of 2W400

    Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material

    Our 2W street and reading.

     

    Solenoid Water Valve Diaphragm 2W400 0.2 - 0.6Mpa Working Pressure NBR Material

     

     

     

    Notes for installation of solenoid valve

     

    1, first check whether the solenoid valve is consistent with the selection parameters, such as power supply voltage, medium pressure, voltage difference, etc., especially the power supply, if wrong, will burn out the coil. The power supply voltage should meet the rated voltage fluctuation range: ac +10%~-15%, dc +10%~-10%, the coil assembly should not be disassembled at ordinary times.

     

    2. Before taking over the pipe, wash the pipe to remove metal powder, sealing material residue and rust. Attention should be paid to the cleanliness of the medium, if the medium is mixed with dirt, impurities and other obstacles to the normal work of the solenoid valve, the pipeline should be installed with a filter or mesh.

     

    3, the general solenoid valve solenoid coil components should be vertical upward, vertical installation in the horizontal pipe on the ground, if limited by space or operating conditions must be installed on the side, when the selection of the order. Otherwise the solenoid valve may not work properly.

     

    4, the solenoid valve should be added before and after the manual cut off valve, at the same time should be set up bypass, easy to maintain the solenoid valve in case of failure.

     

    5, solenoid valve is generally directional, can not be installed backwards, usually in the valve body with → pointing out the direction of medium flow, the installation should be in accordance with the → indicated direction of installation. But in the vacuum pipeline or special circumstances can be installed back.

     

    6, if the media will be water hammer phenomenon, then should choose a waterproof hammer function of the solenoid valve or take corresponding preventive measures.

     

    7, try not to let the solenoid valve in the state of power for a long time, so easy to reduce the service life of the coil or even burn out the coil, that is to say, normally open, normally closed solenoid valve is not interchangeable use.

     

    8, steam electromagnetic valve inlet side should be equipped with a trap, the pipe should be inclined.

     


    Installation steps:
    1.The threaded interface around the ribbons
    2.According to the direction of access to the solenoid valve
    3.According to the standard access power supply
    4.Detection of sealing and circuit

     

     

    If you want to know more,feel free to concats us us..

     

     