Home ProductsPneumatic Pulse Valve

DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil

DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil

    • DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil
    • DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil
    • DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil
    • DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil
  • DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil

    Product Details:

    Place of Origin: CHINA
    Brand Name: Brando
    Certification: CE
    Model Number: CA76MM

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 set
    Price: negotiation
    Packaging Details: Inner Box,Carton,Pallet
    Delivery Time: 4-9 days
    Payment Terms: T/T, Western Union, L/C, MoneyGram
    Supply Ability: 165000 pieces per month
    Contact Now
    Detailed Product Description
    Port Size: G3'';DN80 Material: Aluminum
    Media: Compressed Clean Air Application: Pulse Jet Bag House
    Power: Pneumatic Pressure: 2 Bar - 6 Bar
    Structure: Embedded Diaphragm Valve Temperature Of Media: -5℃~+55℃
    Type: Normally Closed Voltage: AC110V/AC220V/DC24V/DC12V

    DN80 Port CA/RCA76MM Aluminum Pulse Jet Solenoid Valve With AC220V/DC24V Voltage Coil

     

    As the filtration progresses, when the dust on the surface of the filter bag reaches a certain amount, the cleaning valve closes the poppet valve according to the set program, opens the CA76MM pulse jet solenoid pulse valves to blow, shakes off the dust on the filter bag, and falls into the ash bucket. Discharged through the ash discharge valve. The dust collector is provided with a bypass flue. When the boiler (or incinerator) is started, the bypass flue is opened to prevent the oil from burning when the ignition is not good, the oil sticks to the filter bag, and the filter bag is burned in case of an open flame. The bypass is turned on when the boiler has an accidental exhaust gas temperature that exceeds the allowable temperature of the filter bag.

     

    The bag filter has a high purification efficiency, and the efficiency of capturing fine dust is also more than 99%, and the efficiency ratio is high. The dust-containing gas enters the ash hopper of each unit by the diversion tube. After the large particle dust is separated under the guidance of the ash bucket diversion system, it directly falls into the ash hopper, and the remaining dust enters the middle tank filtration zone with the airflow, and the filtered clean gas is thoroughly filtered. The filter bag is discharged through the upper box, the poppet valve, and the exhaust duct.

     

    Technical parameter of G3'' inch port size CA76MM aluminum alloy pulse jet valve:

    Models CA50MM CA62MM CA76MM CA89MM CA102MM
    Nonimal Diameter φ50 φ62 φ76 φ89 φ102
    Port Size (Inches) G2'' G2-1/2'' G3'' G3'' G4''
    Weighgt (kg) 2.5 3 4 4 3.9
    Working Pressure 0.2 Mpa - 0.6 Mpa
    Environment Temperature -5℃-55℃; can be customized
    Relative Humidity ≤85%
    Operating Medium Compressed dry clean air
    Protection Class IP 65
    Service Life Over 1000000 times
    Voltage DC24V/AC110V/AC220V; can be customized

     

    Main dimnesion of AC220V DC24V CA76MM pulse diaphragm valves:

    DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil

     

    Multi-angle display of CA76MM embedded electromagnetic pulse valve:

    DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil

     

    Machining, testing & packing display of double diaphragms CA76MM pulse solenoid valves:

    DN80 Port Aluminum Pneumatic Pulse Valve Jet Solenoid Valve With AC220V / DC24V Voltage Coil

     

    Common CA76MM pulse jet solenoid valve failures and causes:

     

    Fault phenomenon Reasons
    Input electric signal, the pilot head does not move, the diaphragm does not move, and the valve does not work. The line is unreachable; the voltage is too low; due to improper installation on site, the pilot head is stuck.
    The electric signal is input, the pilot head moves in place, and the electromagnetic pulse valve cannot be blown. The unloading hole has poor blocking and exhausting, and the first moving column has a card phenomenon.
    When the electrical signal is input, the diaphragm jumps in place and the pulse valve cannot be blown. The pilot head moving column is beating, the large diaphragm damping hole wear becomes larger, the damping effect becomes smaller; the small diaphragm damping hole is blocked, and the unloading and exhausting is not smooth.
    The electrical signal disappears and the pilot head cannot be reset.
     

    There are burrs or impurities, which cause the moving column to be stuck; the spring is fatigued, the elastic force is insufficient; the damping hole is blocked, the pressure gas is too late or the air pressure is low.

     

    The electrical signal disappears and the diaphragm cannot be reset and shut down.

    The damping hole is blocked, the damping effect is too large, the pressure gas cannot be placed in time; the static pressure is low; the unloading hole is not closed in time.

     

    The electrical signal disappears and the diaphragm cannot be reset and closed.

    The damping hole is blocked; the relief hole is not closed.

     

    The pilot valve coil heats up and burns out. The voltage is high; the DC24V voltage is specified, and the AC220V voltage is input to make the current too large.
    At a pressure of 0.5 MPa or more, the diaphragm cannot be opened. The damping hole wear becomes large.
    At a pressure below 0.4 MPa, the diaphragm cannot be closed. The orifice is blocked; the static pressure is reduced.
    The electrical signal is input, the diaphragm cannot be opened, and the valve cannot be blown. The pilot valve does not work; the small diaphragm orifice and the relief orifice are blocked.
    In any state, the valve can't be closed and it is always ventilated. It is possible that the inlet and outlet directions of the pulse valve are reversed.

     

    Welcome to your inquiry!

    Contact Details
    Ningbo Brando Hardware Co., Ltd

    Contact Person: Echo

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products