Send Message
Home ProductsPulse Jet Valve

Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve

Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve

  • Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve
  • Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve
  • Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve
  • Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve
Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve
Product Details:
Place of Origin: CHINA
Brand Name: BRANDO
Certification: ISO,CE
Model Number: CAC25FS
Payment & Shipping Terms:
Minimum Order Quantity: 1 pc
Price: negotiation
Packaging Details: Box,Carton
Delivery Time: 5-8Work Days
Payment Terms: L/C, D/P, T/T, Western Union, MoneyGram
Supply Ability: 10000 pcs per month
Contact Now
Detailed Product Description
Port Size: 1" Inch Material: Aluminum
Application: Dedusting Power: Solenoid
Structure: Diaphragm Type: Normal Colse
High Light:

pulse jet valves

,

pulse solenoid valve

Right Angle 1" Inch Flange Solenoid Pulse Valve Aluminum Dedusting Valve CAC25FS

 

Advantage:

1. Electromagnetic pulse valve has various models and is widely used.

2. The system is simple, easy to install, and the price is low.

3. The external leakage is blocked, the internal leakage is easy to control, and the use is safe.

4, using imported diaphragm and coil
5, the pilot seal uses argon arc welding
6. Adopt foreign surface treatment technology and international standards

 

Material of CAC25FS

Valve Body ADC 12 aluminum alloy
Circlip 304 stainless steel
Pilot assembly 430FR stainless steel and other materials
Diaphragm Imported nitrile rubber
spring 321 stainless steel
fastener 302 stainless steel

 

Technical Data

Working pressure 0.3~0.8Mpa
Relatively humidity <85%
Working medium Clear Air
Voltage AC110V/AC220V/DC24V
Ambient Temperature for -5~50°C

 

Dimension Drawing of Solenoid Pulse Valve

Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve 0

Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve 1

 

Model Working Pressure Voltage Port size Weight Packing Dimension
CAC25FS 0.3-0.8MPa AC110V/220V/DC24V

1 1/2” in

1” out

1.145kg

 

12x8x21cm

 

Production line of Pulse Valve

Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve 2

Right Angle 1" Inch Flange Pulse Solenoid Valve / Aluminum Dust Collector Valve 3

Right angle pulse valve working principle:

High pressure gas is connected from the air inlet and enters the lower air chamber

1. When the pulse valve is not energized, the gas enters the decompression chamber through the constant pressure pipe of the upper and lower casings and the throttle hole therein. Since the valve core blocks the pressure relief hole under the action of the spring, the gas is not discharged. The pressure between the decompression chamber and the lower chamber is made uniform, and under the action of the spring, the diaphragm blocks the nozzle and the gas does not rush out.

2.When the pulse valve is energized, the valve core is lifted up by the electromagnetic force, the pressure relief hole is opened, and the gas is ejected. Due to the action of the constant pressure pipe orifice, the outflow speed of the pressure relief hole is greater than that of thedecompression chamber. The inflow velocity of the pressure tube gas causes the pressure in the decompression chamber to be lower than the pressure in the lower chamber, and the gas in the lower chamber elevates the diaphragm, opens the nozzle, and performs gas injection.

Installation

1.The pulse valve is directly installed on the flange seat of the outer wall of the air bag. The spray pipe crosses the air bag. Install the valve manual to match the appropriate blow pipe and mounting parts. Try to avoid flipping the valve at the bottom of the air bag. The air outlet pipe and the bulkhead connector are arranged, the bulkhead connector is fixed to the blow pipe and the air bag, and the blow pipe and the air bag must be additionally fixed.
2.tighten the bulkhead nut, the maximum torque 20N.M, tighten the air outlet, the torque is 20 cattle Mimi
3.Connect the control wires to the terminal block of each electronically controlled valve. Note that the inlet port cannot be prevented from flowing upwards, or the air control valve and electromagnetic assembly box are connected through a joint and a length of nylon tube.
4.ensure that the compressed gas source is dry, provide moderate air pressure to the air bag system and check whether there is installation leak, pressure inflating the air bag, it is recommended to inflate the air bag with a maximum pressure of 0.8mpa
5.Test the pulse sequence of the pulse valve, and test whether all the pilot valves are operating normally, and whether the pulse blowing sound is crisp.
6.right angle, submerged, and straight-through electromagnetic pulse valve installation methods can be based on the above description

 

please care the products details at our website, any confuse please contact us or Note your request online. Big quantity purchase ,please contact our online service to ask more economic shipping way or discuss the more pretty price.

 

Welcome our inquiry!

 

 

Contact Details
Ningbo Brando Hardware Co., Ltd

Contact Person: Brandon

Tel: +8613454729544

Send your inquiry directly to us
Best Products
Other Products