Home ProductsPneumatic Cylinder Valve

Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series

Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series

    • Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series
    • Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series
    • Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series
    • Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series
  • Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series

    Product Details:

    Place of Origin: China
    Brand Name: OEM
    Certification: CE、ISO
    Model Number: 4V410-15

    Payment & Shipping Terms:

    Minimum Order Quantity: 3 pc
    Price: negotiation
    Packaging Details: inner boxes,cartons,pallets
    Delivery Time: 7 working days
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 100000pcs per month
    Contact Now
    Detailed Product Description
    Media: Air Application: Automation Equipment
    Structure: Control Product Name: Air Control Valve
    Body Material: Aluminum Alloy Size: 1/2''

    1/2 Inch Inner Pilot Series Lead Wire Type Pneumatic Valve 4V410-15 Application in Automation Machine

     

    4V400 series solenoid pneumatic valve with pilot mode, external and internal optional.

    With sliding column structure, good sealing, responsive characteristics;

    And, 3 kinds of position solenoid valve have central function to offer a choice, its inside control USES special craft to process, attrition resistance is small, start air pressure is low, service life is long, additionally double head 2 position solenoid valve has memory function.

     

    Model 4V410-15 4V420-08 4V430-015
    Position No. Two-Position Five-Way Three-Position Five Way
    Effective sectional area 50mm2 30mm2
    Port size 1/2’’ 1/2’’
    Fluid 40 micron filtered air
    Action style Internal pilot
    Working pressure range 0.15-0.8MPa
    Ambient Temp 5~50’C
    Voltage range ±10%
    Power consumption AC:4.5VA DC:3W
    Insulation and Protection Class F IP65
    Highest Action Frequency 5 Cycle/Second
    Shortest Excitation Time 0.05 Second

     

    Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series

    Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series

     

    Lead Wire Type Pneumatic Cylinder Operated Valve 1/2 Inch Inner Pilot Series

     

     

    Instructions:
    1. check the components before use, whether they are damaged during transportation, then install and use them.
    2. when installing, please pay attention to the direction of gas flow and whether the nozzle is correct.
    3. Installation, pay special attention to whether the voltage meets the requirements, the whole machine debugging, it is recommended to use manual device debugging, and then

    power-on debugging.
    4. please pay attention to dust prevention and suggest installing muffler at the exhaust port.
    5.When connecting the pipeline, pay attention to the winding of the stop strip not to exceed the tooth end surface, and pay attention to the elimination of pipe joints, metal

    particles in the pipe, dust and oil pollution.

     

     
    Pneumatic solenoid valve daily maintenance and maintenance:
    1. Regularly disassemble and clean the internal pneumatic impurities, and check whether the various parts of the pneumatic solenoid valve are seriously worn, and consider replacing or repairing damaged parts according to actual conditions.
    2. When disassembling the pneumatic solenoid valve, first install the power supply and other connections, and pay attention to the installation sequence of the various components of the solenoid valve during the disassembly process.
    3, pneumatic solenoid valve is prone to failure problems are mainly coils and seals and other consumable parts, coil burnout is caused by overload work, the seal itself is a wearing part, mostly due to long hours of work Caused by natural wear and tear.
    4. When the pneumatic solenoid valve is working, if the vibration occurs frequently, it will easily cause damage to the pneumatic solenoid valve components. Therefore, the maintenance of the solenoid valve should also ensure the stability of the working environment, and periodically the pneumatic solenoid valve components. Fix, such as a snail Mother bolts, etc.
    5. If the working environment of the pneumatic solenoid valve is open air, it may cause the rust of the pneumatic solenoid valve and parts to make the solenoid valve unable to work normally. Therefore, maintenance is required to ensure stable operation.
    6. Under the permissible conditions, if the working position of the pneumatic solenoid valve is important, special maintenance personnel are required to ensure the working stability and low failure rate of the solenoid valve. This will make it more efficient, lower maintenance costs and longer life. Pneumatic electricity The maintenance method of the magnetic valve is similar to that of the general valve type. In the actual use and maintenance process, the user can refer to the relevant instructions for proper maintenance and maintenance operations. This has an extended service life for pneumatic solenoid valves and other valves. positive effects.
     

    Contact Details
    Ningbo Brando Hardware Co., Ltd

    Contact Person: Echo

    Send your inquiry directly to us (0 / 3000)