Home ProductsRefrigeration Solenoid Valve

EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve

EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve

    • EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve
    • EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve
    • EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve
    • EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve
  • EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve

    Product Details:

    Place of Origin: CHINA
    Brand Name: Brando
    Certification: CE
    Model Number: EVR3-014

    Payment & Shipping Terms:

    Minimum Order Quantity: 2 sets
    Price: negotiation
    Packaging Details: Inner Boxs,Cartons,Pallet
    Delivery Time: 4-10 days
    Payment Terms: L/C, T/T, Western Union,Paypal
    Supply Ability: 4600 sets per month
    Contact Now
    Detailed Product Description
    Port Size: ODF Material: Brass
    Power: Solenoid Temperature Of Media: -10°C-100°C
    Application: Refrigerant Structure: Control
    Pressure: 3.5MPa Media: Refrigerant
    Voltage: DC12V,AC220V,AC380V Refrigerant: HCFC/CFC/HFC(customer Specified)

    EVR3-014 Refrigeration System Solenoid Valve Brass Body 1/4 Inch SAE Small Size Valve

     

    The EVR refrigeration electromagnetic valve is controlled by a pilot head as general solenoid valve, and the pilot head is controlled by a coil that is energized or not.The difference is the change in the medium and body material that is circulated.There are different materials in EVR refrigeration solenoid valves that pass ammonia and Freon.

     

    Technical Parameters of EVR3-014 Electromagnetic Valve In Refrigeration:

    Model number: Connection: H1 H2 H4 L L2

    KV values:

    (m³/h)

    SAE inlet/outlet ODF inlet/outlet Inch mm Inch mm Inch mm Inch mm Inch mm Inch mm
    EVR3-014 EVR3-014S 1/4 6 0.5 14 2.8 71 - - 4.0 102 0.3 7 0.27
    EVR3-038 EVR3-038S 3/8 10 0.5 14 2.9 73 - - 4.6 117 0.4 10
    EVR6-038 EVR6-038S 3/8 10 0.5 14 3.1 79 - - 4.4 111 0.4 10 0.8
    EVR6-012 EVR6-012S 1/2 12.8 0.5 14 3.1 79 - - 5.0 127 0.4 10
    EVR10-012 EVR10-012S 1/2 12.8 0.6 16 3.1 79 - - 5.0 127 0.4 10 1.9
    EVR10-058 EVR10-058S 5/8 16 0.6 16 3.1 79 - - 6.3 160 0.5 12
      EVR15-058S 5/8 16 0.7 19 3.4 86 - - 6.9 176 0.5 12 2.6
      EVR15-078S 7/8 22 0.7 19 3.4 86 - - 6.9 176 0.7 17
      EVR20-078S 7/8 22 0.8 20 3.5 90 - - 7.5 191 0.7 17 5
      EVR20-118S 1 1/8 28.8 0.8 20 3.5 90 - - 8.4 214 0.8 22
      EVR22-138S 1 3/8 35 0.8 20 3.5 90 - - 11.1 281 1 25 6
      EVR25-118S 1 1/8 28.8 1.5 38 5.4 138 2.8 72 10.0 256 0.8 22 10
      EVR25-138S 1 3/8 35 1.5 38 5.4 138 2.8 72 11.0 281 1 25
      EVR32-138S 1 3/8 35 1.9 47 4.4 111 2.1 53 11.0 281 1 25 16
      EVR32-158S 1 5/8 42 1.9 47 4.4 111 2.1 53 11.0 281 1.1 29
      EVR40-158S 1 5/8 42 1.9 47 4.4 111 2.1 53 11.0 281 1.1 29 25
      EVR40-218S 2 1/8 54 1.9 47 4.4 111 2.1 53 11.0 281 1.3 34

     

    Sperate parts chart of EVR3-014 Refrigeration System Solenoid Valve:

    EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve

     

    Overall dimension of EVR3-014 refrigeration brass solenoid valve:

    EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve

     

    Production Environment of EVR3-014 solenoid valve in refrigeration:

    EVR3-014 Air Conditioner Solenoid , 1/4 Inch Small Normally Closed Solenoid Valve

     

    What is the ice machine with EVR refrigeration solenoid valve?

    Refrigeration machinery -- an ice machine that generates water by cooling the refrigerant in the refrigeration system through an evaporator. After passing through a certain device in the electrified state, ice is generated by the water carrier using the refrigeration system. Depending on how the evaporator works and how it is produced, the ice is shaped differently.

     

    Ice machine with EVR solenoid valve in refrigeration working principle:

    It is a closed refrigerant cycle heat transfer process. The water from the external water source enters the water tank, and the circulating pump pumps the water into the ice machine's water distributor. The water is sprayed evenly on the inner wall of the evaporator by the water distributing board. The heat exchange of the water in the evaporator makes the ice quickly condense into a layer of ice. Driven by a reducer, the spiral skates slowly cut the ice counterclockwise. Under the action of gravity, the borneol falls into the lower freezer, and the unfrozen water falls along the inner wall of the evaporating cylinder. The water plate works in the water channel, and the working principle of the ice machine is transferred to the water tank for the next cycle.

     

    Unit module: including compressor, accumulator, refrigeration pipeline, refrigeration solenoid valve, control box, etc.

     

    Evaporator module: including evaporator, ice tray lifting, ice tray and other supporting equipment.

     

    Welcome to your inquiry!

    Contact Details
    Ningbo Brando Hardware Co., Ltd

    Contact Person: Echo

    Send your inquiry directly to us (0 / 3000)

    Best Products
    Other Products