1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector

1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector

    • 1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector
    • 1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector
    • 1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector
    • 1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector
  • 1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector

    Product Details:

    Place of Origin: Brando
    Brand Name: OEM
    Certification: CE、ISO
    Model Number: CA35T

    Payment & Shipping Terms:

    Minimum Order Quantity: 1Pcs,Sample Available
    Price: USD2.00-50.00 per pc
    Packaging Details: inner boxes,cartons,cases,pallets
    Delivery Time: 7 working days
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 100000pcs per month
    Contact Now
    Detailed Product Description
    Application: Dust Collect System Type: Goyen Type
    Specification: 1 1/4 Inch Material: Aluminum Alloy
    Voltage: Allow AC And DC Name: Pulse Valve

    Efficient Dust collector,Pneumatic Pulse Valve CA35T,1 1/2 Inch Pipe Size
     
    Goyen type pneumatic pulse valve CA35T,with 90 degree angle,1 1/4inch pipe size,application for dust collector.
    Working pressure for 0.3-0.8MPa,the voltage DC 24V,AC 110V 220V are available,the medium is cleaning air/dry compressed air.
    Environment temperature:﹣5-55℃,relative humidity:<85%,working life:up to injection 1 million or more.

     

    We are engaged in manufacturing, exporting and supplying a wide range of pulse jet valve to our respected clients. Clients can avail these in different sizes, shapes and as per their own specifications. We also offer these to our clients at affordable prices. Our ranges of valves are widely used to remove the dust from the filter bags and appreciated for its easy installation, long service life and corrosion resistance.

     

    Use period
    Failure phenomena
    Possible Reason
    Troubleshooting
    During installation and commissioning
    The valves cannot all be opened, but the leading part does act.
    Check the gas dome pressure to see if it is too low.
    Check the leakage
    Some valves do not work, but the others are normal.
    Check the valve coil connection and coil
    Replace the accessories
    The valves cannot all be closed. There is leakage. There is no way to establish a gas dome.
    Y-valve. Some valves for the same gas dome are leaking, thus causing leakage for all the valves.
    Check the leakage
    Z-valve. The valve inlet and blowing muzzle are installed backwards.
    Re-install
    Some valves cannot be closed. There is leakage.
    There is some dirt or debris on the membrane, ii is blocking the moving iron core.
    Clean the membrane and check that the membrane is complete. Check the moving iron core and air lock.
    A valve closing is slowly.
    The membrane orifice is blocked.
    Dredge the membrane orifice
    During use period
    Some valves are leaking. The membrane cannot close tightly and the valve is always open a
    little.
    There is some dirt or debris on the membrane, the leading part is damaged. Moving iron core is blocked.
    Clean the membrane and check that the membrane piece is complete. Check the moving iron core and the air lock. Replace the accessories if necessary.
    Coil is hot and burned out.
    It has been turned on for too long.
    Check the working condition of the control system.
    Voltage exists but the valve does not operate.
    Membrane is damaged and the orifice is blocked.
    Replace the accessories in time.
    Ambient temperature is below -20℃. The valve is leaking and cannot open.
    Ambient temperature is too low and here is frost in the valve.
    Pay attention to insulation and maintaining proper temperatures.

     

    Fefer to the corresponding drawings of CA35T includes various detailed datas
    1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector

     

    We make sure the mothly production more than 100000 pcs
     
    1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector 

     

    Corresponding fittings such as diaphragm also can be available

    1 1/4 Inch Pipe Size Pneumatic Pulse Valve CA35T Efficient Dust Collector

     


     
     
    Performance and cost-effectiveness are essential for dust collector systemsdust collector systems in a wide range of industries, including the following:


    1.Concrete Processing
    2.Grain, Agriculture and Feed
    3.Metal Working (Abrasive Blasting)
    4.Food Processing
    5.Foundries
    6.Pharmaceutical
      
    1. Diaphragm K3500/K3501 are suitabled for the pulse valve of Goyen sizes, CA35T, RCA35T. K3500 was made of Nitrile, K3501 was made of Viton. Both of the diaphragm's size are 1 1/2".
    2. K3501 has excellent high temperature performance, so it was much expensive than the K3500.
     
    FRL ,Brass Valve , Pneumatic Solenoid Valve
    06=1/8 08=1/4 10=3/8 15=1/2 OR 01=1/8 02=1/4 03=3/8 04=1/2 06=3/4 08=1
    Angle Seat Valve,Pulse Valve , Mechanical Valve ,Pneumatic Silencer
    06=1/8 08=1/4 10=3/8 15=1/2 20=3/4 25=1 32=1-1/4 40=1-1/2 50=2 65=2-1/2 80=3
    Needle Valve ,Pneumatic Fitting :01=1/8 02=1/4 03=3/8 04=1/2 06=3/4 08=1
    Ball Valve :04=1/8 06=1/4 08=3/8 15=1/2 20=3/4 25=1 32=1-1/4 40=1-1/2 50=2
    Check Valve :08=1/4 10=3/8 12=1/2 16=3/4 20=1 25=1-1/4 30=1-1/2 40=2


     
    Look forward to your inquiry!And any question will be answered at once!

     